Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Braz. j. oral sci ; 22: e238439, Jan.-Dec. 2023. tab
Artigo em Inglês | LILACS, BBO | ID: biblio-1512207

RESUMO

Various forms of temporary resins are offered on the market; however, the properties of temporary resins obtained by milling and 3D printing have not been fully examined. This study aimed to compare the flexural strength and Vickers hardness of milled and 3D-printed resins. Methods: Three resins were tested: Evolux PMMA (milled resin), Cosmos Temp (3D-printed resin), and Structur 2 SC (bis-acrylic resin, group control). Specimens were prepared with rectangular shapes (n = 12) for flexural strength measurements and disc shapes (n = 9) for Vickers hardness tests. Flexural strength tests were performed at a crosshead speed of 0.75 mm/min, and the Vickers hardness was measured under a load of 20 N for 10 s. The obtained data were subjected to the Kruskal­Wallis test. Results: A significant difference (p < 0.05) in flexural strength was observed among the three sample groups: Evolux PMMA (111.76 MPa), Structur 2 SC (87.34 MPa), and Cosmos Temp (56.83 MPa). No significant difference (p < 0.05) was observed between the Vickers hardness values of Structur 2 SC (33.37 VHN) and Evolux PMMA (29.11 VHN); however, both materials were statistically superior to Cosmos Temp (10.90 VHN). Conclusion: While the mechanical properties of the milled resin were superior or similar to those of the bisacrylic resin, the 3D-printed resin was statistically inferior to both the milled and bis-acrylic resins


Assuntos
Desenho Assistido por Computador , Restauração Dentária Temporária , Resinas , Resistência à Flexão , Testes de Dureza
2.
Rev. odontol. UNESP (Online) ; 44(2): 99-102, Mar-Apr/2015. tab, ilus
Artigo em Inglês | LILACS, BBO | ID: lil-746235

RESUMO

Introduction: Accurate dimensions of cast-metal posts are relevant to the survival of dental prostheses. Objective: The aim of this study was to verify if the dimensions of cast-metal posts accord with ideal clinical criteria. Material and method: For the evaluation, 285 periapical radiographs, from a total of 80 teeth, were taken from the charts of patients that attended the clinics at the Dental School of the Federal University of Goiás, from March 2008 to October 2012. Only periapical radiographs of single-rooted teeth with post and core were included in the study. The radiographic evaluation was conducted with the assistance of a magnifying glass and a view box, in a room with low luminosity. The dimensions of the post and core were established with the help of a digital caliper, and the following measurements were considered: a) LR (Length Remnant); b) LP (Length Post); c) BS (Bone Support); d) DR (Diameter Root); e) DP (mesiodistal diameter post). The post and core were classified as acceptable or deficient by reference values with a margin of error of 0.2 mm. For descriptive analysis, the data were cataloged using SPSS software (version 17.0). Result: With regard to the length of the post and core, only 26.25% and 43.75% of the post and core were classified as acceptable according to the two-thirds rule and fulcrum dental rule, respectively. With regard to the mesiodistal diameter of the post and core, 55% were classified as acceptable. Conclusion: Within the limits of this study, it can be concluded that the cast-metal posts evaluated do not accord with the ideal clinical criteria. .


Introdução: As dimensões corretas de um retentor intrarradicular são bastante relevantes para a longevidade de uma prótese. Objetivo: O objetivo deste estudo foi comprovar se as dimensões de retentores metálicos fundidos estão de acordo com critérios clínicos ideais. Material e método: Foram analisadas 285 radiografias periapicais de diagnóstico, totalizando 80 dentes, de pacientes que procuraram atendimento na Faculdade de Odontologia/UFG, no período de março de 2008 a outubro de 2012. Foram incluídas no estudo as radiografias periapicais de dentes unirradiculares, que apresentavam retentor intrarradicular metálico fundido. A avaliação radiográfica foi realizada em ambiente com pouca luminosidade e com auxílio de um negatoscópio com lupa. A dimensão dos retentores foi estabelecida através de um paquímetro digital considerando as seguintes medidas: a) comprimento do remanescente (CR); b) comprimento do retentor intrarradicular (CRI); c) suporte ósseo (SO), diâmetro mésio-distal da raiz (DR); d) diâmetro mésio-distal do retentor intrarradicular (DRI). Por meio de parâmetros de referência os retentores foram classificados em aceitáveis, com margem de erro de até 0,2 mm, ou deficientes. Para a análise descritiva os dados foram catalogados utilizando-se o software SPSS 17.0. Resultado: Quanto ao comprimento, pela análise da regra dos 2/3 apenas 23,75% dos retentores foram classificados como aceitáveis, enquanto na regra do fulcro dentário essa porcentagem foi de 37,5%. Com relação ao diâmetro mésio-distal 52,5% dos retentores foram aceitáveis. Conclusão: Dentro dos limites deste estudo, pode-se concluir que os retentores metálicos fundidos avaliados não estão de acordo com os critérios clínicos ideais. .


Assuntos
Controle de Qualidade , Radiografia Dentária , Técnica para Retentor Intrarradicular , Prótese Parcial Fixa
3.
Stomatos ; 18(34): 60-70, Jan.-Jun. 2012. tab
Artigo em Inglês | LILACS, BBO | ID: lil-693976

RESUMO

The purpose of this cross-sectional study was to evaluate the prevalence of abutment teeth for conventional fixed prostheses in a Brazilian subpopulation. Panoramic radiographs for a total of 1,401 patients taken from August 2002 to September 2007 were randomly selected from the database of the Radiological Center of Orofacial Images of Cuiabá (Cuiabá, Brazil). A total of 1,401 radiographs were examined to determine the frequency of abutment teeth for conventional fixed prostheses. Data concerning age, sex, and dental group were recorded. Frequency distribution and the chi-square test were used for statistical analysis. The level of significance was set at α = 5%. Of the 29,467 teeth included in the evaluation, 4,967 (16.8%) were abutments for conventional fixed prostheses. A high prevalence of abutment teeth for conventional fixed prostheses was observed in individuals aged between 46 and 60 years (49.9%). Maxillary canines and second premolars were the teeth most often involved in rehabilitation (10.5% and 10.3%). Missing teeth were identified in 24.8% of the sample. The prevalence of abutment teeth for conventional fixed prostheses was 16.8%, and the teeth most frequently used were maxillary canines and maxillary second premolars.


O objetivo deste estudo transversal foi avaliar a prevalência de dentes pilares de próteses fixas convencionais em uma subpopulação brasileira. Radiografias panorâmicas de um total de 1.401 pacientes, realizadas entre agosto de 2002 e setembro de 2007, foram aleatoriamente selecionadas do banco de dados do Centro de Radiologia e Imagens Orofaciais de Cuiabá (Cuiabá, MT, Brasil). Um total de 1.401 imagens radiográfi cas foram examinadas para a determinação da prevalência de dentes pilares de prótese fixa convencional. Dados referentes a idade, gênero e grupo dentário foram coletados e tabulados. O tratamento estatístico analisou os dados frente à distribuição de frequência e o teste qui-quadrado. O nível de significância foi de α = 5%. Foram avaliados 29.467 dentes, dos quais 4.967 (16,8%) eram pilares de prótese fixa convencional. Elevada prevalência de dentes pilares de prótese fixa convencional foi observada em indivíduos da faixa etária de 46- 60 anos (49,9%). Caninos superiores e segundos pré-molares superiores foram os dentes mais frequentemente envolvidos nas reabilitações: 10,5 e 10,3%, respectivamente. Ausências dentárias foram identificadas em 24,8% da amostra. A prevalência de dentes pilares associados com prótese fixa convencional foi de 16,8%, sendo mais frequente em caninos superiores e segundos prémolares superiores.


Assuntos
Humanos , Interpretação Estatística de Dados , Medidas em Epidemiologia , Prótese Dentária , Prótese Parcial Fixa , Radiografia Panorâmica
4.
Braz. dent. j ; 23(2): 127-134, Mar.-Apr. 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-626300

RESUMO

Acceptable therapeutic protocol in dentistry depends on the outcomes obtained with follow up. Operative procedural errors (OPE) may occur and they represent risk factors able to compromise a tooth or a dental implant. The aim of this study was to detect the OPE in endodontically treated teeth and dental implants, using cone beam computed tomography (CBCT).Eight hundred and sixteen CBCT exams were performed between January 2009 and October 2010, and only those which presented endodontically treated teeth and/or dental implants were selected. The sample was as follows: 195 CBCT exams (n=200 teeth and 200 dental implants), 72 male, 123 female, with mean age of 51 years.In endodontically treated teeth, OPE included underfilling, overfilling, and root perforation; OPEin dental implants were thread exposures, contact with anatomical structures, and contact with adjacent teeth. Kolmogorov-Smirnov test was used for statistical analysis, with significance level set at α=0.05. Underfilling, overfilling, and root perforations were detected in 33.5%, 8% and 4.5% of the teeth, respectively. Dental implants with thread exposures, contact with important anatomical structures and contact with adjacent teeth were seen in 37.5%, 13% and 6.5% of the cases, respectively. OPE were detected in endodontically treated teeth and dental implants, and underfilling and thread exposures were the most frequent occurrences, respectively.


Protocolos terapêuticos aceitáveis em odontologia dependem de resultados observados com a proservação. Erros de procedimentos operatórios podem ocorrer e representam fatores de risco capazes de comprometer um dente ou um implante dentário. O objetivo deste artigo é detectar os erros de procedimentos operatórios em dentes tratados endodonticamente e implantes dentários por meio de tomografia computadorizada de feixe cônico. Oitocentos e dezesseis (816) exames tomográficos foram realizados entre Janeiro de 2009 e Outubro de 2010, e apenas aqueles que apresentaram dentes tratados endodonticamente e/ou implantes dentários foram selecionados. A amostra final envolveu 195 exames tomográficos (n=200 dentes e 200 implantes dentários), 72 do gênero masculino, 123 do gênero feminino, com idade média de 51 anos. Em dentes tratados endodonticamente os erros de procedimentos operatórios incluídos foram: subobturação, sobreobturação, e perfuração radicular; enquanto que, para implantes dentários foram incluídos: roscas de implantes expostas, implantes em contato com estruturas anatômicas, e em contato com dentes adjacentes. O nível de significância foi estabelecido em α=5%. Subobturações, sobreobturações e perfurações radiculares foram detectadas em 33,5%, 8% e 4,5%, respectivamente. Implantes dentários com roscas expostas, em contato com estruturas anatômicas, e em contato com dentes adjacentes apresentaram valores de 37,5%, 13% e 6,5%, respectivamente. Erros de procedimentos operatórios foram detectados em dentes tratados endodonticamente e implantes dentários. Os erros mais frequentes foram subobturação em dentes tratados endodonticamente, e roscas expostas em implantes dentários.


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Implantes Dentários , Imageamento Tridimensional/métodos , Tratamento do Canal Radicular , Raiz Dentária , Dente não Vital , Tomografia Computadorizada de Feixe Cônico , Estudos Transversais , Erros Médicos
5.
Braz. oral res ; 24(2): 147-152, Apr.-June 2010. tab
Artigo em Inglês | LILACS | ID: lil-553900

RESUMO

This study analyzed the reaction layer and measured the marginal crown fit of cast titanium applied to different phosphate-bonded investments, prepared under the following conditions (liquid concentration/casting temperature): Rema Exakt (RE) - 100 percent/237°C, 75 percent/287°C, Castorit Super C (CS)-100 percent/70°C, 75 percent/141°C and Rematitan Plus (RP)- 100 percent/430°C (special to titanium cast, as the control group). The reaction layer was studied using the Vickers hardness test, and analyzed by two way ANOVA and Tukey's HSD tests (á = 0.05). Digital photographs were taken of the crowns seated on the die, the misfit was measured using an image analysis system and One-way ANOVA, and Tukey's test was applied (á = 0.05). The hardness decreased from the surface (601.17 VHN) to 150 ìm (204.03 VHN). The group CS 75 percent/141°C presented higher hardness than the other groups, revealing higher surface contamination, but there were no differences among the groups at measurements deeper than 150 ìm. The castings made with CS - 100 percent/70°C presented the lowest levels of marginal misfit, followed by RE -100 percent/237°C. The conventional investments CS (100 percent) and RE (100 percent) showed better marginal fit than RP, but the CS (75 percent) had higher surface contamination.


Assuntos
Coroas , Adaptação Marginal Dentária , Revestimento para Fundição Odontológica/química , Fosfatos/química , Titânio/química , Análise de Variância , Técnica de Fundição Odontológica , Materiais Dentários , Testes de Dureza , Temperatura Alta , Teste de Materiais , Propriedades de Superfície
6.
ROBRAC ; 17(44): 117-123, dez. 2008. ilus
Artigo em Português | LILACS | ID: lil-524013

RESUMO

A colocação de implantes imediatos em alvéolos após exodontia, representa uma técnica viável dereabilitação, principalmente na região anterior da maxila. Esta técnica apresenta as vantagens de eliminaralguns meses de espera para ossificação do alvéolo, possível manutenção da altura e largura do ossoalveolar, manutenção e regeneração dos tecidos moles, redução dos procedimentos cirúrgicos e resultadosestéticos imediatos, pelo uso de restaurações provisórias. Diante destas vantagens e das elevadastaxas de sucesso alcançadas com os implantes imediatos, o objetivo deste trabalho foi descrever um casoclínico de um incisivo lateral superior esquerdo que foi extraído, devido à perda de implantação óssea, ecolocação imediata de implante e coroa provisória.


The placement of immediate implants on socket after tooth extraction, represent a feasible techniqueof rehabilitation, mainly in the esthetic zone of the anterior maxilla. This technique presents the advantagesto eliminate waiting many months for ossification of the socket, possible maintenance of alveolarbone height and width, maintenance and regeneration of soft tissues, reduction of surgical procedures andfavorable immediate esthetic results, by use of provisional restorations. In front of these advantages and ofthe success rates high reached with immediate implants, the aim of this work was to explain a clinical caseof a upper left lateral incisor that was extracted, due the loss of bone implantation and performed the immediateplacement of implant in the tooth socket.

7.
J. appl. oral sci ; 15(4): 247-252, July-Aug. 2007. ilus, tab
Artigo em Inglês | LILACS | ID: lil-463673

RESUMO

As the adaptation of titanium crowns obtained by Rematitan Plus investment, specific for titanium, is not recognized to be suitable, this study evaluated the effect of the concentration of the specific liquid and the temperature of the mold of investments on the internal misfit of crowns cast on commercially pure titanium. Individual dies of epoxy resin were obtained, representing teeth prepared for full-crown restoration with a 6-degree axial surface convergence angle and shoulder (1.0 mm). For the waxing of each crown, a ring-shaped stainless steel matrix (8.0mm internal diameter; 7.5 mm height) was adapted above the individual dies of epoxy resin. The Rematian Plus investment was mixed according to the manufacturer's instructions using two different concentrations of the specific liquid: 100 percent, 75 percent. Casting was performed in a Discovery Plasma Ar-arc vacuum-pressure casting machine with molds at temperatures of 430°C, 515°C and 600°C. The crowns were cleaned individually in a solution (1 percent HF + 13 percent HNO3) for 10 min using a ultrasonic cleaner, with no internal adaptations, and luted with zinc phosphate cement under a 5 kg static load. The crown and die assemblies were embedded in resin and sectioned longitudinally. The area occupied by cement was observed using stereoscopic lens (10X) and measured by the Leica Qwin image analysis system (mm²). The data for each experimental condition (n=8) were analyzed by Kruskal-Wallis non-parametric test (á=0.05). The results showed that liquid dilution and the increase in mold temperature did not significantly influence the levels of internal fit of the cast titanium crowns. The lowest means (±SD) of internal misfit were obtained for the 430°C/100 percent: (7.25 mm² ±1.59) and 600°C/100 percent (8.8 mm² ±2.25) groups, which presented statistically similar levels of internal misfit.

9.
Rev. odontol. UNESP ; 36(1): 41-46, jan.-mar. 2007. tab
Artigo em Português | LILACS, BBO | ID: lil-529251

RESUMO

O objetivo deste trabalho foi avaliar a prevalência dos diferentes fatores etiológicos de dor miofascial nos pacientes atendidos na Clínica de Dor Orofacial da Faculdade de Odontologia de Araraquara - UNESP. Foram catalogadas 273 fichas clínicas de pacientes atendidos nos anos de 2003 e 2004, compreendendo 239 pacientes do gênero feminino e 34 do masculino, com idade entre 10 e 73 anos, e de todas as etnias. Foram incluídos os pacientes que apresentaram diagnóstico de dor miofascial, podendo haver outros diagnósticos de desordens temporomandibulares associados, como dor muscular local, mioespasmo ou desordens funcionais da ATM. Foram excluídos pacientes que apresentavam diagnóstico de desordens sistêmicas (fibromialgia, lupus eritematoso ou AIDS). Entre os resultados obtidos foi observado que, na amostra estudada, os hábitos parafuncionais foram os fatores mais relevantes (87%), seguidos de postura inadequada do sono (76%), postura inadequada de trabalho (61%), reduzida ingestão de água (49%), distúrbios do sono (48%), número inadequado de refeições (36%), baixo condicionamento físico (27%), elevado consumo de cafeína (27%) e distúrbios endócrinos ou metabólicos (15%).


The aim of this study was to evaluate the prevalence of the different etiologic factors of myofascial pain in patients seen at the Orofacial Pain Clinic of the Araraquara Dental School/UNESP. 273 treatment charts were analyzed. The charts referred to patients who were seen during the past two years, 239 females and 34 males, ages ranged from 10 to 73 years. The patients had been diagnosed for myofascial pain, but could also present other associated craniomandibular disorders, such as regional muscular pain, cramps or temporomandibular dysfunctions. Patients were excluded from the study if they presented systemic disorders (fibromyalgia, lupus erythematosus or AIDS). Among the results obtained can be observed that in sample studied, the parafunctional habits were the more relevant factors with 87%, followed of the inadequate sleep posture (76%), inadequate occupational activity (61%), reduced water ingestion (49%), sleep disturbances (48%), inadequate number of meals (36%), low physical conditioning (27%), high caffeine use (27%) and metabolic and endocrine disorders (15%).


Assuntos
Dor Facial , Prevalência
10.
J. appl. oral sci ; 15(1): 44-48, Jan.-Feb. 2007. tab, ilus
Artigo em Inglês | LILACS | ID: lil-450010

RESUMO

The aim of the work was to evaluate the influence of the temperature of investment healting on the tensile strength and Vickers hardness of CP Ti and Ti-6Al-4V alloy casting. Were obtained for the tensile strength test dumbbell rods that were invested in the Rematitan Plus investment and casting in the Discovery machine cast. Thirty specimens were obtained, fiftten to the CP Titanium and fifteen to the Ti-6Al-4V alloy, five samples to each an of the three temperatures of investment: 430°C (control group), 480°C and 530°C. The tensile test was measured by means of a universal testing machine, MTS model 810, at a strain of 1.0 mm/min. After the tensile strenght test the specimens were secctioned, embedded and polished to hardness measurements, using a Vickers tester, Micromet 2100. The means values to tensile tests to the temperatures 430°C, 480 and 530: CP Ti (486.1 - 501.16 - 498.14 -mean 495.30 MPa) and Ti-6Al-4V alloy (961.33 - 958.26 - 1005.80 - mean 975.13 MPa) while for the Vickers hardness the values were (198.06, 197.85, 202.58 - mean 199.50) and (352.95, 339.36, 344.76 - mean 345.69), respectively. The values were submitted to Analysis of Variance (ANOVA) and Tukey,s Test that indicate differences significant only between the materials, but not between the temperature, for both the materias. It was conclued that increase of the temperature of investment its not chance the tensile strength and the Vickers hardness of the CP Titanium and Ti-6Al-4V alloy.

11.
Ciênc. odontol. bras ; 9(3): 19-25, jul.-set. 2006. tab
Artigo em Inglês | LILACS, BBO | ID: lil-457445

RESUMO

O objetivo deste estudo foi avaliar os efeitos da polimerização térmica adicional na resistência à flexão de compósitos diretos. Os espécimes dos compósitos diretos (Z250 e P60) (n=10), medindo 25×2×2 mm, foram polimerizados por três métodos: (1) fotopolimerização por 40 segundos, (2) (1) + polimerização adicional em estufa a 120°C por 20 minutos, e (3) (1) + polimerização adicional em autoclave a 120°C por 20 minutos. Os espécimes (n=10) do compósito indireto Artglass (grupo controle) foram polimerizados no forno UniXS. Os espécimes foram armazenados em água destilada por 24 horas a 37°C e então submetidos ao teste de resistência à flexão. Os dados de resistência à flexão foram analisados por análise de variância e teste Tukey (α=0,05). Os resultados mostraram que (1) a polimerização térmica adicional em estufa resultou em resistência à flexão significativamente maior (p<0,05) (Z250: 158,85 MPa e P60: 147,10 MPa) que a resina Artglass (121,52 MPa); (2) com a polimerização em autoclave, os compósitos diretos apresentaram médias de resistência à flexão (Z250: 134,54 MPa e P60: 130,18 MPa) similares à resina Artglass (p>0,05); (3) os grupos apenas fotopolimerizados (Z250: 124,75 MPa e P60: 128,96 MPa) foram similares à resina Artglass (p>0,05). Quando os compósitos foram apenas fotopolimerizados, eles mostraram comportamento de resistência à flexão similar ao compósito indireto Artglass.


Assuntos
Resinas Compostas , Luz/efeitos adversos , Teste de Materiais , Maleabilidade , Análise de Variância
12.
Rev. odontol. UNESP ; 35(3): 171-175, jul.-set. 2006. tab
Artigo em Português | LILACS, BBO | ID: lil-512578

RESUMO

O titânio apresenta características favoráveis que o torna uma excelente alternativa ao uso de ligas áureas, porém seu elevado ponto de fusão e a baixa densidade exigem máquinas especiais de fundição e revestimento resistente para suportar o processo. Esse estudo avaliou a resistência à compressão de três revestimentos fosfatados, sendo um deles específico para titânio Rematitan Plus (RP) e dois alternativos, Rema Exakt (RE) e Castorit Super C (CA), variando-se a temperatura final do ciclo (600, 515 e 430 °C). Para o ensaio de resistência à compressão, os corpos-de-prova cilíndricos (n = 10) com 20 mm de diâmetro e 40 mm de altura foram obtidos em uma matriz metálica bipartida. Após 12 horas, foram submetidos à queima em forno (EDG) conforme instruções do fabricante. Ao atingir a temperatura final programada, foi realizado o teste, em máquina de ensaios mecânicos MTS 810, à velocidade de 2 mm.min-1 até a fratura do corpo-de-prova. Após os testes, os valores de resistência em MPa foram analisados por meio do software SPSS 11.0. Aplicou – se análise de variância e teste de Tukey para comparação dos grupos (P = 0,05). Em cada temperatura, o RE apresentou maior resistência que o RP, que, por sua vez, foi superior ao CA. Analisou-se, também, a influência das temperaturas para cada material. Em geral, os materiais na temperatura final de 600 °C foram mais resistentes do que em 515 e 430 °C, que mostraram comportamento variável. Concluiu-se que o revestimento alternativo RE apresentou resistência à compressão superior à do específico para titânio e que a variação na temperatura final influenciou diferentemente cada material.


The titanium has favorable characteristics that become an excellent alternative to the use of golden alloys. However, his high point of fusion and the low density require special machines of castingand resistant dental investments for this process.This study evaluated the strength to the compression of three phosphate-bonded investments, one of them specific for titanium - Rematitan Plus (RP), and two alternative Rema Exakt (RE) and Castorit Super C (CA), in different end temperatures of the cycle (600, 515 and 430 °C). For the strength to the compression, cylindrical specimens with 20 mm of diameter and 40 mm of height were obtained in a bipartite metallic matrix (n = 10), after 12 hours were submitted to the burns in oven (EDG), in according to the instructions of the manufacturer. Upon reaching the end programmed temperature, was done the test in machine of mechanical test MTS 810 (MTS System Corporation, Minnesota, EUA), in speed of 2mm.min_1 up to fracture of the specimens. After the tests the values of resistance in MPa were analyzed utilizing the software SPSS 11.0. It applied – itself ANOVA and test of Tukey for comparison of the groups (P = 0.05) and compared the material in each temperature, the RE presented bigger resistance than to of the RP, that by his time was a superior to of the CA. Analyzed itself the influence of the temperatures for each material. The materials in the end temperature of 600 °C were more resistant than in 515 and 430 °C. It was possible to conclude that the dental investments RE showed highest strength than the specific investment and the final temperature influenced differently this property of the materials.


Assuntos
Prótese Dentária , Revestimento para Fundição Odontológica , Titânio
13.
Braz. dent. j ; 17(2): 126-129, 2006. tab
Artigo em Inglês | LILACS | ID: lil-433499

RESUMO

O objetivo deste estudo foi avaliar o efeito de tratamentos térmicos na dureza Vickers do titânio comercialmente puro e da liga Ti-6Al-4V. Corpos-de-prova cilíndricos com 6 mm de diâmetro foram fundidos no sistema Rematitan. Os corpos-de-prova de titânio comercialmente puro e da liga Ti-6Al-4V foram divididos aleatoriamente em 3 grupos (n=10): controle (sem tratamento térmico); tratamento 1 (T1): aquecido a 750ºC por 2 h; tratamento 2 (T2): aquecido a 955ºC por 1 h e envelhecido a 620ºC por 2 h. Após os tratamentos térmicos, os corpos-de-prova foram incluídos em resina acrílica, a superfície foi regularizada e polida, e a dureza foi mensurada. As médias de dureza Vickers (VHN) e os desvios padrão foram analisados estatisticamente usando o teste de Kruskal-Wallis com nível de significância a 5%. Para o titânio comercialmente puro, a média de dureza do grupo T2 (259,90 VHN) foi significativamente maior que os outros grupos (controle-200,26 VHN e T1-202,23 VHN) (p<0,05), que apresentaram valores médios similares (p>0,05). Para a liga Ti-6Al-4V, diferenças estatisticamente significantes foram observadas entre os três grupos: T2 (369,08 VHN), T1 (351,94 VHN) e controle (340,51 VHN) (p<0,05). Os resultados demonstraram diferente comportamento de dureza do titânio comercialmente puro e da liga Ti-6Al-4V quando diferentes tratamentos foram usados. Para o titânio comercialmente puro, a média de VHN grupo T2 foi consideravelmente maior que as médias dos grupos controle e T1, os quais demonstraram médias similares entre si. Para a liga Ti-6Al-4V, entretanto, a média de VHN registrada para cada grupo pode ser apresentada da seguinte maneira: T2>T1>controle.


Assuntos
Temperatura Alta , Titânio/química , Dureza , Distribuição Aleatória
14.
Araraquara; s.n; 2005. 145 p. ilus, tab.
Tese em Português | LILACS, BBO | ID: lil-466876

RESUMO

O objetivo deste estudo foi avaliar o efeito da concentração do líquido especial e da temperatura do molde dos revestimentos Rematitan Plus, específico para titânio, Rema Exakt e Castorit Super C, alternativos, na desadaptação marginal de coroas fundidas em titânio puro. Moldagens individuais com silicona de adição foram usadas para duplicar o troquel padrão de aço inoxidável e obter troquéis de resina epóxi. O troquel representa um preparo de coroa total de um molar com as seguintes dimensões: altura (6,0mm), ombro (1,0mm), diâmetro cervical (7,0mm), diâmetro oclusal (5,7mm), e com ângulo de convergência da superfície axial de 6º. O enceramento de cada coroa foi realizado no troquel individual de resina epóxi. Para o revestimento Rematitan Plus os padrões de cera foram incluídos à vácuo com três diferentes concentrações do líquido especial, 100,75 e 50 percento, diluídos em água destilada. As fundições foram realizadas na máquina Discovery Plasma com os moldes em três temperaturas, 430ºC, 515ºC e 600ºC. Os revestimentos alternativos foram empregados nas condições em que obtiveram...


Assuntos
Ligas Dentárias , Revestimento para Fundição Odontológica , Titânio
15.
J. Health Sci. Inst ; 22(3): 237-242, jul.-set. 2004. CD-ROM
Artigo em Português | LILACS, BBO | ID: biblio-851186

RESUMO

As resinas laboratoriais associadas a estruturas metálicas surgiram como alternativa às porcelanas e às resinas acrílicas. Devido a características como fácil manipulação e excelente estética, as resinas, atualmente, têm ampla aceitação clínica nas próteses e restaurações metaloplásticas, prônticos de próteses parciais e adesivas e overlays de próteses parciais removíveis. A grande limitação do uso das resinas estava relacionada ao mecanismo de retenção na superfície metálica. Os elementos de retenção mecânica inicialmente utilizados contribuíam para as falhas na interface adesiva, criando regiões de concentração de estresse na resina, além de tomarem muito espaço, limitando a espessura da faceta de resina e comprometendo a estética. A popularização do uso das resinas fotopolimerizáveis em facetas estéticas originou alguns métodos de retenção para assegurar sua união química ao metal: resina opaca termopolimerizável, sistemas com abertura de sílica, silanos e primers adesivos para metal, resina opaca autopolimerizável e cimentos adesivos com grupos funcionais para união ao metal. O propósito deste trabalho é abordar o grau de desenvolvimento dos sistemas de retenção química utilizados na união de facetas e resina a estruturas metálicas


Assuntos
Resinas Compostas , Ligas Dentárias , Facetas Dentárias , Estética Dentária , Ligas Metalo-Cerâmicas
16.
Rev. odontol. UNICID ; 14(3): 205-210, set.-dez. 2002.
Artigo em Português | LILACS, BBO | ID: lil-345138

RESUMO

O objetivo deste trabalho foi revisar a literatura e discutir os progressos alcançados no desenvolvimento de técnicas e produtos específicos para adesäo de cerâmicas e compósitos ao titânio. O titânio tem sido o metal de maior destaque na Odontologia atual. A excelente biocompatibilidade do titânio e suas ligas, associada às propriedades mecânicas e à excelente resistência à corrosäo, têm feito do titânio uma nova opçäo nos procedimentos de reabilitaçäo oral. As restauraçöes dentárias confeccionadas totalmente com materiais estéticos (cerâmicas e compósitos) apresentam certas limitaçöes devido à relativa fragilidade destes materiais frente aos estresses mastigatórios. A associaçäo de infra-estruturas metálicas a tais materiais, possibilita restabelecer a forma, funçäo e a harmonia estética do trabalho de reabilitaçäo oral


Assuntos
Titânio , Adesivos , Estética Dentária , Restauração Dentária Permanente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA